mirror of
https://github.com/ChuckBuilds/LEDMatrix.git
synced 2026-10-10 09:06:36 +00:00
The web interface had its own logging setup (web_interface/logging_config.py)
that replaced the root handlers with a plain stdout formatter. The web
service's journal lines therefore never carried a syslog priority, so
`journalctl -p err -u ledmatrix-web` returned nothing while errors were
logged, and the line shape differed from the display's (the log viewer's
prefix stripping only matched the display format). It also ran after the
module-level managers were built, so their INFO lines at import (including
"Re-removed N uninstalled plugin(s)") were dropped.
app.py now calls src.logging_config.setup_logging() first thing, the same as
run.py: journald priorities under systemd, LEDMATRIX_DEBUG honoured,
LEDMATRIX_JSON_LOGGING still selects JSON.
Per-request logging moves to web_interface/request_logging.py. Every request
used to be logged at INFO, so the UI's polling filled the journal
("GET /api/v3/errors/summary - 200" every minute per tab). Now a successful
GET/HEAD/OPTIONS is DEBUG, a successful write is INFO, 4xx WARNING, 5xx
ERROR. Durations use perf_counter and print to 0.1ms.
The duplicate module is deleted; nothing else imported it.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>