- Health check: a failed restart command no longer lets the check run
against the still-running old process; it counts as a failure (and after a
rollback, as a failed rollback). An unreadable restart count is never
treated as stable, since a crash loop looks healthy between attempts.
- Installer writes the auto_update setting to a temp file and swaps it in,
keeping mode and owner, so a running config watcher never reads a
truncated config.json.
- Verify unit quotes its command-line paths (install folders with spaces);
setup refuses folder names systemd would reinterpret (%, quotes,
backslashes, control characters) and says so on the General tab.
- The auto-update status route no longer returns exception text.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
- Replace the subprocess.CompletedProcess the verifier fabricated for a
command that could not start with a plain namedtuple; nothing is executed
there, but the scanner flags any CompletedProcess built from variables.
- Mark the subprocess imports with the repo's standard B404 annotation (all
calls are list-form argv, no shell).
- Mark the rollback-failed message as not SQL (B608 matched its wording).
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
A General-tab toggle (off by default) checks for and installs LEDMatrix and
plugin updates once a week, overnight in the configured timezone.
- Pre-update checks skip (and report) instead of forcing: local edits or
commits, merge/live rebase, no upstream, low disk, missing health check, or
a version that was already rolled back. An abandoned rebase (HEAD back on a
branch) is cleared, since it would otherwise block every pull.
- The pull reuses the Update Code path (now perform_core_update(), which
reports dependency install failures as data).
- ledmatrix-update-verify.service, started via a .path unit from a request
file, restarts the services from its own cgroup, requires them to come up
and stay up, and otherwise resets to the previous commit and reinstalls the
previous requirements. It runs a copy of the checker taken before the pull.
- No SSH needed: switching the toggle on restarts the display service, which
(as root) installs the two units from the repo templates for the web user.
first_time_install.sh installs them too and takes --enable-auto-update /
LEDMATRIX_AUTO_UPDATE (passed through by one-shot-install.sh).
- Plugins update after the code passes its check; failures, blocks and
rollbacks raise an Overview banner and show under the toggle.
Tested end to end on a Pi: web-UI setup, a good update, a broken web service
and a broken display (both rolled back), a blocked local edit, and an
abandoned rebase found on the device.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>